summaryrefslogtreecommitdiff
diff options
context:
space:
mode:
authorMikle Kolyada <zlogene@gentoo.org>2018-03-14 22:18:39 +0300
committerMikle Kolyada <zlogene@gentoo.org>2018-03-14 22:19:07 +0300
commit062e819ca03c57caf93170c4edb6636039d63110 (patch)
treef38bad0186ae07a316dc4376f5d865448b5808c3 /sys-power/apcupsd
parentapp-text/dvisvgm: Remove old (diff)
downloadgentoo-062e819ca03c57caf93170c4edb6636039d63110.tar.gz
gentoo-062e819ca03c57caf93170c4edb6636039d63110.tar.bz2
gentoo-062e819ca03c57caf93170c4edb6636039d63110.zip
sys-power/apcupsd: Drop old
Package-Manager: Portage-2.3.24, Repoman-2.3.6
Diffstat (limited to 'sys-power/apcupsd')
-rw-r--r--sys-power/apcupsd/apcupsd-3.14.14.ebuild136
1 files changed, 0 insertions, 136 deletions
diff --git a/sys-power/apcupsd/apcupsd-3.14.14.ebuild b/sys-power/apcupsd/apcupsd-3.14.14.ebuild
deleted file mode 100644
index 06483304207a..000000000000
--- a/sys-power/apcupsd/apcupsd-3.14.14.ebuild
+++ /dev/null
@@ -1,136 +0,0 @@
-# Copyright 1999-2016 Gentoo Foundation
-# Distributed under the terms of the GNU General Public License v2
-
-EAPI=5
-
-inherit eutils linux-info flag-o-matic systemd udev
-
-DESCRIPTION="APC UPS daemon with integrated tcp/ip remote shutdown"
-HOMEPAGE="http://www.apcupsd.org/"
-SRC_URI="mirror://sourceforge/apcupsd/${P}.tar.gz"
-
-LICENSE="GPL-2"
-SLOT="0"
-KEYWORDS="~amd64 ~arm ~ppc ~x86 ~x86-fbsd"
-IUSE="snmp +usb cgi nls gnome kernel_linux"
-
-DEPEND="
- || ( >=sys-apps/util-linux-2.23[tty-helpers(-)]
- sys-freebsd/freebsd-ubin
- )
- cgi? ( >=media-libs/gd-1.8.4 )
- nls? ( sys-devel/gettext )
- snmp? ( >=net-analyzer/net-snmp-5.7.2 )
- gnome? ( >=x11-libs/gtk+-2.4.0:2
- dev-libs/glib:2
- >=gnome-base/gconf-2.0 )"
-RDEPEND="${DEPEND}
- virtual/mailx"
-
-CONFIG_CHECK="~USB_HIDDEV ~HIDRAW"
-ERROR_USB_HIDDEV="CONFIG_USB_HIDDEV: needed to access USB-attached UPSes"
-ERROR_HIDRAW="CONFIG_HIDRAW: needed to access USB-attached UPSes"
-
-pkg_setup() {
- if use kernel_linux && use usb && linux_config_exists; then
- check_extra_config
- fi
-}
-
-src_prepare() {
- epatch "${FILESDIR}/${PN}-3.14.9-aliasing.patch"
-}
-
-src_configure() {
- local myconf
- use cgi && myconf="${myconf} --enable-cgi --with-cgi-bin=/usr/libexec/${PN}/cgi-bin"
- if use usb; then
- myconf="${myconf} --with-upstype=usb --with-upscable=usb --enable-usb --with-dev= "
- else
- myconf="${myconf} --with-upstype=apcsmart --with-upscable=smart --disable-usb"
- fi
-
- # We force the DISTNAME to gentoo so it will use gentoo's layout also
- # when installed on non-linux systems.
- econf \
- --sbindir=/sbin \
- --sysconfdir=/etc/apcupsd \
- --with-pwrfail-dir=/etc/apcupsd \
- --with-lock-dir=/run/apcupsd \
- --with-pid-dir=/run/apcupsd \
- --with-log-dir=/var/log \
- --with-nis-port=3551 \
- --enable-net --enable-pcnet \
- --with-distname=gentoo \
- $(use_enable snmp) \
- $(use_enable gnome gapcmon) \
- ${myconf} \
- APCUPSD_MAIL=/bin/mail
-}
-
-src_compile() {
- # Workaround for bug #280674; upstream should really just provide
- # the text files in the distribution, but I wouldn't count on them
- # doing that anytime soon.
- MANPAGER=$(type -p cat) \
- emake
-}
-
-src_install() {
- emake DESTDIR="${D}" install
- rm -f "${D}"/etc/init.d/halt || die
-
- insinto /etc/apcupsd
- newins examples/safe.apccontrol safe.apccontrol
- doins "${FILESDIR}"/apcupsd.conf
-
- dodoc ChangeLog* ReleaseNotes
- doman doc/*.8 doc/*.5
-
- dohtml -r doc/manual/*
-
- rm "${D}"/etc/init.d/apcupsd || die
- newinitd "${FILESDIR}/${PN}.init.4" "${PN}"
- newinitd "${FILESDIR}/${PN}.powerfail.init" "${PN}".powerfail
-
- systemd_dounit "${FILESDIR}"/${PN}.service
- systemd_dotmpfilesd "${FILESDIR}"/${PN}-tmpfiles.conf
-
- # remove hal settings, we don't really want to have it around still.
- rm -r "${D}"/usr/share/hal || die
-
- # replace it with our udev rules if we're in Linux
- if use kernel_linux; then
- udev_newrules "${FILESDIR}"/apcupsd-udev.rules 60-${PN}.rules
- fi
-
-}
-
-pkg_postinst() {
- if use cgi; then
- elog "The cgi-bin directory for ${PN} is /usr/libexec/${PN}/cgi-bin."
- elog "Set up your ScriptAlias or symbolic links accordingly."
- fi
-
- elog ""
- elog "Since version 3.14.0 you can use multiple apcupsd instances to"
- elog "control more than one UPS in a single box with openRC."
- elog "To do this, create a link between /etc/init.d/apcupsd to a new"
- elog "/etc/init.d/apcupsd.something, and it will then load the"
- elog "configuration file at /etc/apcupsd/something.conf."
- elog ""
-
- elog 'If you want apcupsd to power off your UPS when it'
- elog 'shuts down your system in a power failure, you must'
- elog 'add apcupsd.powerfail to your shutdown runlevel:'
- elog ''
- elog ' \e[01m rc-update add apcupsd.powerfail shutdown \e[0m'
- elog ''
-
- if use kernel_linux; then
- elog "Starting from version 3.14.9-r1, ${PN} installs udev rules"
- elog "for persistent device naming. If you have multiple UPS"
- elog "connected to the machine, you can point them to the devices"
- elog "in /dev/apcups/by-id directory."
- fi
-}